AM-IOT-ION Digital Water Hardness Sensor

1) Water Hardness (Ca2+) range : 0.02~ 40000mg/L.
2) Chemical formula:F-,Cl-,Ca2+,NO3-,NH4+,K+,NH3,Mg2+,
Br−,Pb2+,Cu2+,CO2,NO2-, Cd,Ag+,I2, SCN-,CLO4-,BF4-,Li+etc
3) Online measure ion value and temperature at same time.
4) Directly with standard RS485 Modbus
5) Protection:IP68 and with waterproof cable
6) Ion membrane can be replaced to save cost.

Product Details

AM-IOT-ION is a digital ion sensor with standard RS485 Modbus communication,it’s developed by Aumeascon. Housing material is corrosion-resistant (PPS+POM), IP68 protection, suitable for most water quality monitoring environments;This online ion sensor uses an industrial-grade composite electrode, the reference electrode double salt bridge design and have longer working life;Built-in temperature sensor and compensation algorithm, high precision; It has been widely used in domestic and foreign scientific research institutions, chemical production, agricultural fertilizer, and organic wastewater industries. It is used for the detection of general sewage, waste water and surface water. It can be installed in sink or flow tank.

Technical Specification

1) Ion membrane can be replaced and save cost.
2) Online ion measurement and temperature at same time.
3) With standard RS485 Modbus.
4) IP68 protection and water proof cable.
5) Special technology for harsh environments.
6) High accuracy , reliability and Quick response time

Technical Parameters of Ion Meter

Model

AM-IOT-ION Digital Ion Sensor

Ions type

F,Cl,Ca2+,NO3,NH4+,K+,NH3,CO2,Mg 2+  , etc.

Range

See below sensor table

Power

12V (customized for 5V,24VDC)

Slope

Monovalent Ion 52~59mV and Divalent Ion22~29mv (25℃)

Accuracy

<±2% 25℃

Response time

<60s (90% right value)

Communication

Standard RS485 Modbus

Temperature compensation

PT1000

Dimension

D:30mm * L:250mm

Cable length

Standard cable:5meters(it can be extended)

(Table 1)

Ion

Formula

Membrane

Range @25

(mg/L)

pHRange

Temp.Range

WorkingPressure

Reference Ion

Potassium ion

K+

PVC

0.04~ 39000

2-12

0~40

0-1Bar

Cs+,NH4+

Ammonium ion

NH4+

PVC

0.02~ 18000

4-10

0~40

0-1Bar

K+

Calcium ion

(Water Hardness)

Ca2+

PVC

0.02~ 40000

2.5~11.5

0~40

0-1Bar

Pb2+,Hg2+,Fe2+,

Cu2+,Ni2+

Magnesium ion

Mg2+

PVC

0.1~24000ppm

3-10

0~40

0-1Bar

Ca2+, Cu2+, Pb2+, Hg2+, Ni2+

Nitrite

NO2

PVC

0.05~460

4-9

0~40

0-1Bar

NO3-, Cl-

(need compensation)

Nitrate

NO3

PVC

0.4 ~63000

2-12

0~40

0-1Bar

CIO4-,I-,CIO3-,F-

Fluoride ion

F

Solid

0.02~saturation

5-8

0~80

0-3Bar

OH-

Chloride

Cl

Solid

1.8 ~35500

2-12

0~80

0-3Bar

CN-,Br,I-,S2-

Ammonia

NH3

PTFE

0.02~ 17000

>11

0~50

0-1Bar

Few, volatile amines

Carbon dioxide

(carbonate)

CO2

PTFE

4.4 ~ 440

4.8-5.2

0~50

0-1Bar

Volatile weak acid

Bromide ion

Br

Solid

0.4~79900

2-14

0~80

0-3Bar

S2-,I-, CN-

Iodide ion

I2

Solid

0.006~126900

0-14

0~80

0-3Bar

S2-,Br-,CN-,Cl-,S2O3-,NH3

Copper ions

Cu 2+

Solid

0.0064~ 6350

2-6

0-80

0-3Bar

Hg2+,Ag+,Fe2+,Br-,Cl-

Lead ions

Pb2+

Solid

0.2~20700

3-8

0-80

0-3Bar

Ag+, Hg2+, Cu2+

Cadmium ions

Cd

Solid

0.01~11200

2-12

0-80

0-3Bar

Ag+,Hg2+,Cu2+,Pb2+,Fe2+

Silver ions

Ag +

Solid

0.01~107900

2-8

0-80

0-3Bar

Hg+,Hg2+,Cl-

Thiocyanate

SCN-

Solid

0.2~58100

2-10

0-80

0-3Bar

S2-,Br-,CN-,Cl-,S2O3-,NH3

Sodiuim ion

Na+

Glass

0.0~23000

5-12

0-80

0-3Bar

K+,H+

Barium ion

Ba2+

PVC

0.005~137000

2-12

0-40

0-1Bar

No obvious interference

Lithium ion

Li+

PVC

0.007~6941

2-9

0-40

0-1Bar

Cs+, K+

Surfactants

 

PVC

Determined by ingredients

2-12

0-40

0-1Bar

Similar cationic and anionic surfactants

Tetrafluoroborate

BF4-

PVC

0.5~10800

2.5-11

0-40

0-1Bar

ClO4-, I-, CN-

Perchlorate

CLO4-

PVC

0.7~99000

2.5-11

0-40

0-1Bar

No obvious interference

Cyanide ion

CN-

Solid

0.13~260

11-13

0-80

0-3Bar

S2-, I-, CN-, Cl-

Sulfide ion

S2-

Solid

0.003~32100

>11

0-80

0-3Bar

Hg2+, Cl-

Dimension of Ion Sensor

Attention of Wire connection

1) Electrode wiring (ION/GLASS: working electrode connected to transparent wire, REF: reference electrode connected to shielded mesh wire, SG: solution ground connected to green wire, TEMP: temperature electrode connected to black and white wire, no positive or negative);

2) Wire extension: When the customer extends or modifies the cable by himself, it is necessary to ensure that the black conductive rubber of the shielded wire core is peeled off and the transparent core is leaked;(Otherwise, the working electrode and the reference electrode are in a short-circuit.

Two-Point Calibration/Slope - User Mode

1) Connect the electrode with the computer through the 485 interface, and connect the power supply to the electrode as required
2) View the mV value of the sensor via Modbus software
3) Write the number “0” into the “1st calibration point target value” register(0x0024) ,”2nd calibration point target value” register (0x0026),”3rd calibration point target value” register(0x0028) ,”4th calibration point target value” register (0x002A), see the holding register list for the register address.
4) Rinse the electrode with pure water, dry the water with a paper towel, put the electrode into the 10 standard solution, turn on the magnetic stirrer and stir evenly at a constant speed, and wait for about 8 minutes for the data to stabilize (so-called stable: potential jump ≤ 0.5mV/min) , Record the value (E1), and write the standard solution concentration “10” into the digital electrode “1st calibration point target value” register(0x0024) through the Modbus software, the register address sees the holding register list;
5) Rinse the electrode with pure water, absorb the water with a paper towel, put the electrode into the 100 standard solution, turn on the magnetic stirrer and stir evenly at a constant speed, and wait for about 8 minutes for the data to stabilize (so-called stable: potential jump ≤ 0.5mV/min) , record the value (E2), and write the standard solution concentration “100” into the digital electrode “target value of the second calibration point” register(0x0026) through the Modbus software, the register address sees the holding register list; when the value of the second calibration point is written into the digital electrode After the corresponding register is set, the calibration is completed.
6) The difference between the two values (E2-E1) is the slope of the electrode.
7 )Monovalent Ion:52~59mV@25℃ : NH4+, K+, NO3-, Cl-, F-, NH3, CO2.
8) Divalent Ion: 22~29mV@25℃ : Ca2+, Mg2+ 

Maily Applications

NO.

Application

Most customers measure below ions.

1

Agriculture

Nitrate, calcium, sodium, potassium, bromide, chloride, ammonia & fluoride

2

Plant Tissue

Nitrate, chloride, fluoride, iodide, cyanide, calcium, sodium and potassium

3

Fertilizer

Nitrate using the ammonia electrode, potassium and fluoride

4

Aquaculture

Ammonia, nitrate, calcium and dissolved oxygen

5

Biomedical Research

Calcium, carbon dioxide and ammonia

6

Education

Various ISEs electrodes are used in most colleges and niversities

7

Food Processing

Chlorides, nitrate, sodium and fluoride

8

Milk and Dairy Products

Chloride, calcium, fluoride, sodium and iodide

9

Soft Drinks

Chloride, fluoride, carbon dioxide and residual chlorine

10

Alcohol

Potassium, sodium, CO2, fluoride, bromide, calcium, and residual chlorine

11

Vegetables

Nitrate, chloride and sodium

12

Geology and Mining

Fluoride, calcium and cyanide

13

Metallurgy and Metal Plating

Fluoride, cupric, cyanide, fluoroborate and nitrate

14

Plating Baths

Chloride, residual chlorine and ammonia

15

Pulp and Paper

Sodium, chloride, calcium and sulfate

16

Petroleum Refining

Ammonia andchloride

17

Pharmaceuticals

Fluoride and soldium

18

Sewage Treatment

Nitrate, ammonia, residual chlorine and dissolved oxygen (BOD)

19

Steam and Power Generation

Chloride, sodium, residual chlorine, fluoroborate and dissolved oxygen

20

Drinking Water

Total, free & residual chlorine, nitrate, calcium, chloride, and fluoride

21

Natural Water

Bromide, calcium, chloride, fluoride, nitrate, potassium, silver, sodium & cupric

22

Sea Water

Sodium, chloride, fluoride, nitrate and ammonia

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “@aumeascon.com”