Level Measurement

Level instruments chosen by range and blind zone, foam, steam, agitation, and whether the medium’s density is stable.

The models on this page, side by side

Same range, different conditions. Rule a model out here by principle, output and lead time before opening it.

Model Principle What it is for Outputs Lead time
AM-FLS Fork Level Switch AM-FLS Point Level Switch Vibrating fork… 7–10 working days for standard
AM-P200 Submersible Level Transmitter AM-P200 Pressure (Hydrostatic) Submersible hy… 4–20 mA · RS485 7–10 working days for standard
AM-P201 Submersible Level Transmitter with LCD Display AM-P201 Pressure (Hydrostatic) Submersible le… 4–20 mA · RS485 7–10 working days for standard
AM-RM 80 GHz Radar Level Meter AM-RM Radar 80 GHz radar l… 4–20 mA · Modbus RTU · HART 7 working days; 15 working days for the explosion-proof version
AM-ULM Ultrasonic Level Meter AM-ULM Ultrasonic Non-contact ul… 4–20 mA · Pulse · Modbus RTU 7 working days; split and explosion-proof versions 15 working days
AM-ULM-B Small Blind Area Ultrasonic Level Meter AM-ULM-B Ultrasonic Short-span ult… 4–20 mA · RS485 · Modbus RTU 7–10 working days for standard
AM-ULM-D Ultrasonic Level Differential Meter AM-ULM-D Ultrasonic Two-probe ultr… 4–20 mA · RS485 · Modbus RTU 7–10 working days for standard
AM-ULM-EX Explosion-proof Ultrasonic Level Meter AM-ULM-EX Ultrasonic Explosion-proo… 4–20 mA · RS485 · Modbus RTU 7–10 working days for standard
AM-ULM-S Split Type Ultrasonic Level Meter AM-ULM-S Ultrasonic Split ultrason… 4–20 mA · HART · RS485 · Modbus RTU 7–10 working days for standard
AM-USM Ultrasonic Sludge Level Meter AM-USM Sludge / Interface Ultrasonic slu… 4–20 mA · Modbus RTU 7 working days; an on-site commissioning check adds 3 working days
AM-FLS Fork Level Switch

AM-FLS

AM-FLS Fork Level Switch

Vibrating fork point-level switch for tanks of powder or liquid: one answer, wet or dry, and no calibration to drift.

Point Level Switch
AM-P200 Submersible Level Transmitter

AM-P200

AM-P200 Submersible Level Transmitter

Submersible hydrostatic level transmitter, 0–200 m, 0.2 or 0.5 % FS, 4–20 mA and RS485, IP68 sensor on a vented cable.

Pressure (Hydrostatic) 4–20 mA RS485
AM-P201 Submersible Level Transmitter with LCD Display

AM-P201

AM-P201 Submersible Level Transmitter with LCD Display

Submersible level transmitter with a local LCD display — the P200 series: 0–200 m, 0.2/0.5 % FS, RS485 and 4–20 mA, IP68.

Pressure (Hydrostatic) 4–20 mA RS485
AM-RM 80 GHz Radar Level Meter

AM-RM

AM-RM 80 GHz Radar Level Meter

80 GHz radar level transmitter for foam, steam, dust and pressurised tanks, 0 to 30 m.

Radar 4–20 mA Modbus RTU HART
AM-ULM Ultrasonic Level Meter

AM-ULM

AM-ULM Ultrasonic Level Meter

Non-contact ultrasonic level meter for tanks, sumps and channels, 0 to 15 m.

Ultrasonic 4–20 mA Pulse Modbus RTU
AM-ULM-B Small Blind Area Ultrasonic Level Meter

AM-ULM-B

AM-ULM-B Small Blind Area Ultrasonic Level Meter

Short-span ultrasonic level meter for shallow wells and tanks: 0–3 m, blind zone under 0.1 m, ±0.15 % and 1 mm resolution, 4–20 mA or Modbus.

Ultrasonic 4–20 mA RS485 Modbus RTU
AM-ULM-D Ultrasonic Level Differential Meter

AM-ULM-D

AM-ULM-D Ultrasonic Level Differential Meter

Two-probe ultrasonic differential level meter: 0–25 m difference range, ±0.5 %, two relays, 90–240 V AC or 12–24 V DC, 4–20 mA and Modbus.

Ultrasonic 4–20 mA RS485 Modbus RTU
AM-ULM-EX Explosion-proof Ultrasonic Level Meter

AM-ULM-EX

AM-ULM-EX Explosion-proof Ultrasonic Level Meter

Explosion-proof ultrasonic level meter for hazardous areas: Ex db ia IIC T6 Gb, 0–30 m, ±0.5 %, 1 mm resolution, 4–20 mA and RS485.

Ultrasonic 4–20 mA RS485 Modbus RTU
AM-ULM-S Split Type Ultrasonic Level Meter

AM-ULM-S

AM-ULM-S Split Type Ultrasonic Level Meter

Split ultrasonic level meter for deep wells, silos and tanks: 0–30 m, blind zone 0.25–0.8 m, ±0.5 %, 10 m cable extendable to 70 m.

Ultrasonic 4–20 mA HART RS485
AM-USM Ultrasonic Sludge Level Meter

AM-USM

AM-USM Ultrasonic Sludge Level Meter

Ultrasonic sludge blanket and interface meter for settling tanks and clarifiers.

Sludge / Interface 4–20 mA Modbus RTU