Products

The whole catalogue, grouped by measurement principle. Open a model for its specifications, its limits and its downloads.

AM-CON Inductive Conductivity Sensor

AM-CON

AM-CON Inductive Conductivity Sensor

Inductive (toroidal) conductivity sensor for aggressive and fouling liquids, RS485 Modbus.

Conductivity Modbus RTU 4–20 mA
AM-D-PH Digital pH Sensor

AM-D-PH

AM-D-PH Digital pH Sensor

Digital online pH sensor with RS485 Modbus, for continuous monitoring in wastewater and process water.

Online Analyzer Modbus RTU 4–20 mA
AM-DFM Doppler Flow Meter

AM-DFM

AM-DFM Doppler Flow Meter

Doppler ultrasonic flow meter for sludge, slurry and raw wastewater carrying solids or bubbles.

Doppler 4–20 mA Pulse Modbus RTU
AM-IOT-ION Digital Ion Sensor

AM-IOT-ION

AM-IOT-ION Digital Ion Sensor

Digital ion-selective sensor for online ammonia nitrogen and other ions, with a replaceable membrane.

Ion Sensor Modbus RTU 4–20 mA
AM-LTF Liquid Turbine Flow Meter

AM-LTF

AM-LTF Liquid Turbine Flow Meter

Liquid turbine flow meter for clean, low-viscosity liquids, with a wide turndown and a pulse output.

Turbine Pulse 4–20 mA Modbus RTU
AM-MFM Electromagnetic Flow Meter

AM-MFM

AM-MFM Electromagnetic Flow Meter

Obstructionless electromagnetic flow meter for conductive liquids and two-phase slurries, DN6–DN2600, with five liners and seven electrode materials.

Electromagnetic 4–20 mA Pulse HART
AM-OCFM Open Channel Flow Meter

AM-OCFM

AM-OCFM Open Channel Flow Meter

Open channel flow meter for flumes, weirs and non-standard channels, with user-entered head-flow tables.

Open Channel 4–20 mA Modbus RTU Pulse
AM-P100 Pressure Sensor

AM-P100

AM-P100 Pressure Sensor

Industrial pressure transmitter for pump station pipework and process pressure, 4-20 mA and HART.

Pressure Transmitter 4–20 mA HART Modbus RTU
AM-P104 Digital Pressure Controller

AM-P104

AM-P104 Digital Pressure Controller

Digital pressure controller for pump start-stop, interlocks and alarm logic, with two relay outputs.

Pressure Controller 4–20 mA Pulse
AM-P200 Submersible Level Transmitter

AM-P200

AM-P200 Submersible Level Transmitter

Submersible hydrostatic level transmitter for wet wells, tanks and reservoirs, 0 to 200 m.

Pressure (Hydrostatic) 4–20 mA Modbus RTU
AM-RM 80 GHz Radar Level Meter

AM-RM

AM-RM 80 GHz Radar Level Meter

80 GHz radar level transmitter for foam, steam, dust and pressurised tanks, 0 to 30 m.

Radar 4–20 mA Modbus RTU HART
AM-ULF-W Wall Mounted Ultrasonic Flow Meter

AM-ULF-W

AM-ULF-W Wall Mounted Ultrasonic Flow Meter

Wall-mounted clamp-on ultrasonic flow meter for existing pipes, DN15 to DN6000, installed without cutting the line.

Clamp-on Ultrasonic 4–20 mA Pulse Modbus RTU
AM-ULM Ultrasonic Level Meter

AM-ULM

AM-ULM Ultrasonic Level Meter

Non-contact ultrasonic level meter for tanks, sumps and channels, 0 to 15 m.

Ultrasonic 4–20 mA Pulse Modbus RTU
AM-USM Ultrasonic Sludge Level Meter

AM-USM

AM-USM Ultrasonic Sludge Level Meter

Ultrasonic sludge blanket and interface meter for settling tanks and clarifiers.

Sludge / Interface 4–20 mA Modbus RTU

Content plan — catalogue filters

  • Range filter: nominal size or measuring range, so a visitor can rule out models that do not fit the pipe.
  • Principle filter: electromagnetic, ultrasonic, Doppler, thermal, radar, hydrostatic — the choice an engineer makes first.
  • Output filter: 4–20 mA, pulse, Modbus RTU/TCP, HART, MQTT, for the control system already installed.
  • Planned as a filter–sort behaviour over the same product query, with the chosen filters in the URL.