Sludge / Interface
AM-USM Ultrasonic Sludge Level Meter
Ultrasonic sludge blanket and interface meter for settling tanks, measuring the sludge line and the clear-water interface from a fixed top mount.
- Model
- AM-USM
- Category
- Sludge / Interface
- Outputs
- 4–20 mA, Modbus RTU
- Lead time
- 7 working days; an on-site commissioning check adds 3 working days
- MOQ
- 1 unit
- OEM available
- Yes
Technical specifications
| Measurement | Sludge blanket level and interface, 0.3–10 m |
|---|---|
| Principle | Dual-frequency ultrasonic, fixed-top installation |
| Accuracy | ±1% of range in stable sludge |
| Outputs | Two 4-20 mA channels, RS485 Modbus, relay per threshold |
| Protection | IP68 probe, IP65 controller |
| Installation | Fixed mount on the tank bridge or a handrail bracket |
What it is not the answer for
Read this before asking for a price: one of these conditions is what turns a good meter into a bad installation.
- Thin, well-mixed sludge where no clear interface exists to measure
- Tanks with mechanical scrapers passing within the probe's measurement path
- Very deep tanks beyond the stated range
Maintenance and service life
Clean the probe monthly in heavy sludge service. Re-run the blanket calibration after any change to the sludge draw-off schedule, because the profile, not the instrument, has usually changed. The probe has no moving parts.
Behind the instrument
How it is built and tested
Coil winding, the calibration bench, the plant floor — and an overseas customer's factory audit.
Applications
Where this model is used
Each application names a measuring point and the conditions that decide the selection.
Measuring point does not match the table above?
Send the medium, the pipe size and the output your control system expects. We answer with the principle that fits, or with the reason none of ours does.