Products

The whole catalogue, grouped by measurement principle. Open a model for its specifications, its limits and its downloads.

AM-CON Inductive Conductivity Sensor

AM-CON

AM-CON Inductive Conductivity Sensor

Inductive conductivity sensor for aggressive, scaling or fouling liquids, with no electrodes in contact with the medium.

Conductivity Modbus RTU 4–20 mA
AM-D-PH Digital pH Sensor

AM-D-PH

AM-D-PH Digital pH Sensor

Digital online pH sensor for continuous monitoring in wastewater and process water, with Modbus output and a replaceable electrode.

Online Analyzer Modbus RTU 4–20 mA
AM-DFM Doppler Flow Meter

AM-DFM

AM-DFM Doppler Flow Meter

Doppler ultrasonic flow meter for sludge, slurry and raw wastewater where the liquid carries enough solids or bubbles to reflect the signal.

Doppler 4–20 mA Pulse Modbus RTU
AM-IOT-ION Digital Ion Sensor

AM-IOT-ION

AM-IOT-ION Digital Ion Sensor

Digital ion-selective sensor for continuous ammonia nitrogen and other ion measurement, with a replaceable membrane and a refillable reference.

Ion Sensor Modbus RTU 4–20 mA
AM-LTF Liquid Turbine Flow Meter

AM-LTF

AM-LTF Liquid Turbine Flow Meter

Liquid turbine flow meter for clean, low-viscosity liquids, with a wide turndown and a pulse output for batch control.

Turbine Pulse 4–20 mA Modbus RTU
AM-MFM Electromagnetic Flow Meter

AM-MFM

AM-MFM Electromagnetic Flow Meter

Obstructionless electromagnetic flow meter for conductive liquids and two-phase slurries, DN6–DN2600, with five liners and seven electrode materials.

Electromagnetic 4–20 mA Pulse HART
AM-OCFM Open Channel Flow Meter

AM-OCFM

AM-OCFM Open Channel Flow Meter

Open channel flow meter for flumes, weirs and non-standard channels, with the site's own head-flow table entered directly.

Open Channel 4–20 mA Modbus RTU Pulse
AM-P100 Pressure Sensor

AM-P100

AM-P100 Pressure Sensor

Industrial pressure transmitter for pump station pipework and process lines, with a stainless diaphragm and a 4-20 mA HART output.

Pressure Transmitter 4–20 mA HART Modbus RTU
AM-P104 Digital Pressure Controller

AM-P104

AM-P104 Digital Pressure Controller

Digital pressure controller for pump start-stop and alarm logic, with two relays and a retransmitted 4-20 mA signal.

Pressure Controller 4–20 mA Pulse
AM-P200 Submersible Level Transmitter

AM-P200

AM-P200 Submersible Level Transmitter

Submersible hydrostatic level transmitter for wet wells, tanks and reservoirs, with a vented cable and a diaphragm protected against rags.

Pressure (Hydrostatic) 4–20 mA Modbus RTU
AM-RM 80 GHz Radar Level Meter

AM-RM

AM-RM 80 GHz Radar Level Meter

80 GHz radar level transmitter for foam, steam, dust and pressurised tanks, with a beam narrow enough to fit a small nozzle.

Radar 4–20 mA Modbus RTU HART
AM-ULF-W Wall Mounted Ultrasonic Flow Meter

AM-ULF-W

AM-ULF-W Wall Mounted Ultrasonic Flow Meter

Wall-mounted clamp-on ultrasonic flow meter for existing pipes, installed without cutting the line or stopping the process.

Clamp-on Ultrasonic 4–20 mA Pulse Modbus RTU
AM-ULM Ultrasonic Level Meter

AM-ULM

AM-ULM Ultrasonic Level Meter

Non-contact ultrasonic level meter for open tanks, sumps and channels, with a small blind zone and a Modbus output.

Ultrasonic 4–20 mA Pulse Modbus RTU
AM-USM Ultrasonic Sludge Level Meter

AM-USM

AM-USM Ultrasonic Sludge Level Meter

Ultrasonic sludge blanket and interface meter for settling tanks, measuring the sludge line and the clear-water interface from a fixed top mount.

Sludge / Interface 4–20 mA Modbus RTU

Content plan — catalogue filters

  • Range filter: nominal size or measuring range, so a visitor can rule out models that do not fit the pipe.
  • Principle filter: electromagnetic, ultrasonic, Doppler, thermal, radar, hydrostatic — the choice an engineer makes first.
  • Output filter: 4–20 mA, pulse, Modbus RTU/TCP, HART, MQTT, for the control system already installed.
  • Planned as a filter–sort behaviour over the same product query, with the chosen filters in the URL.