Products 27 models

Every model, with its principle, its range and its outputs, so a shortlist is two clicks away.

AM-CMFM Coriolis Mass Flow Meter

AM-CMFM

AM-CMFM Coriolis Mass Flow Meter

Coriolis mass flow meter that reads mass, density and temperature from one tube — DN1–DN150, for dosing and recipe lines.

Coriolis 4–20 mA Pulse RS485
AM-CON Inductive Conductivity Sensor

AM-CON

AM-CON Inductive Conductivity Sensor

Inductive conductivity sensor for aggressive, scaling or fouling liquids, with no electrodes in contact with the medium.

Conductivity Modbus RTU 4–20 mA
AM-D-DFM Doppler Flow Sensor

AM-D-DFM

AM-D-DFM Doppler Flow Sensor

RS485 Doppler flow sensor, not a meter: 0.03–5 m/s velocity, 0.05–10 m level, 7.2–15 V DC, for a host to compute flow.

Doppler RS485
AM-D-PH Digital pH Sensor

AM-D-PH

AM-D-PH Digital pH Sensor

Digital online pH sensor for continuous monitoring in wastewater and process water, with Modbus output and a replaceable electrode.

Online Analyzer Modbus RTU 4–20 mA
AM-DFM Doppler Flow Meter

AM-DFM

AM-DFM Doppler Flow Meter

Doppler flow meter for channels, manholes and partly filled pipes: surface velocity plus water level, no weir or flume required.

Doppler 4–20 mA RS485 Modbus RTU
AM-FLS Fork Level Switch

AM-FLS

AM-FLS Fork Level Switch

Vibrating fork point-level switch for tanks of powder or liquid: one answer, wet or dry, and no calibration to drift.

Point Level Switch
AM-IMFM Insertion Type Electromagnetic Flow Meter

AM-IMFM

AM-IMFM Insertion Type Electromagnetic Flow Meter

Insertion electromagnetic flow meter for existing large mains, DN300–DN3000 — fitted through a 2-inch ball valve, no pipe cut-out.

Electromagnetic 4–20 mA Pulse RS485
AM-IOT-ION Digital Ion Sensor

AM-IOT-ION

AM-IOT-ION Digital Ion Sensor

Digital ion-selective sensor for continuous ammonia nitrogen and other ion measurement, with a replaceable membrane and a refillable reference.

Ion Sensor Modbus RTU 4–20 mA
AM-LTF Liquid Turbine Flow Meter

AM-LTF

AM-LTF Liquid Turbine Flow Meter

Liquid turbine flow meter for clean, non-abrasive liquids: DN4–DN200, ±0.5 % of reading (±0.2 % on the accurate build), pulse, 4–20 mA, RS485.

Turbine Pulse 4–20 mA RS485
AM-MFM Electromagnetic Flow Meter

AM-MFM

AM-MFM Electromagnetic Flow Meter

Obstructionless electromagnetic flow meter for conductive liquids and two-phase slurries, DN6–DN2600, with five liners and seven electrode materials.

Electromagnetic 4–20 mA RS485 Pulse
AM-OCFM Open Channel Flow Meter

AM-OCFM

AM-OCFM Open Channel Flow Meter

Open channel flow meter: ultrasonic level converted through a weir or Parshall flume, 3 m level standard, 4–20 mA and RS485.

Open Channel 4–20 mA Modbus RTU Pulse
AM-P100 Pressure Sensor

AM-P100

AM-P100 Pressure Sensor

Diffused-silicon pressure transmitter, −0.1 to 100 MPa at 0.25 % FS, 316L diaphragm, 4–20 mA or RS485, IP65.

Pressure Transmitter 4–20 mA RS485
AM-P104 Digital Pressure Controller

AM-P104

AM-P104 Digital Pressure Controller

Digital pressure controller for pump start-stop and alarm logic, with two relays and a retransmitted 4-20 mA signal.

Pressure Controller 4–20 mA Pulse
AM-P200 Submersible Level Transmitter

AM-P200

AM-P200 Submersible Level Transmitter

Submersible hydrostatic level transmitter, 0–200 m, 0.2 or 0.5 % FS, 4–20 mA and RS485, IP68 sensor on a vented cable.

Pressure (Hydrostatic) 4–20 mA RS485
AM-P201 Submersible Level Transmitter with LCD Display

AM-P201

AM-P201 Submersible Level Transmitter with LCD Display

Submersible level transmitter with a local LCD display — the P200 series: 0–200 m, 0.2/0.5 % FS, RS485 and 4–20 mA, IP68.

Pressure (Hydrostatic) 4–20 mA RS485
AM-RM 80 GHz Radar Level Meter

AM-RM

AM-RM 80 GHz Radar Level Meter

80 GHz radar level transmitter for foam, steam, dust and pressurised tanks, with a beam narrow enough to fit a small nozzle.

Radar 4–20 mA Modbus RTU HART
AM-TFS Thermal Flow Switch

AM-TFS

AM-TFS Thermal Flow Switch

Thermal flow switch for water, oil and air lines: a repeatable contact at a set velocity, PNP/NPN or relay output, IP67 probe.

Flow Switch
AM-ULF-H Handheld Ultrasonic Flow Meter

AM-ULF-H

AM-ULF-H Handheld Ultrasonic Flow Meter

Handheld clamp-on ultrasonic flow meter for DN15–DN6000: ±1 % of reading, 2000-line logger, RS-232, over 12 hours per charge.

Clamp-on Ultrasonic
AM-ULF-P Portable Ultrasonic Flow Meter

AM-ULF-P

AM-ULF-P Portable Ultrasonic Flow Meter

Portable clamp-on ultrasonic flow meter for DN15–DN6000: 20-hour battery, built-in thermal printer, ±1 % of reading, RS485.

Clamp-on Ultrasonic RS485
AM-ULF-W Wall Mounted Ultrasonic Flow Meter

AM-ULF-W

AM-ULF-W Wall Mounted Ultrasonic Flow Meter

Wall-mounted clamp-on ultrasonic flow meter for existing pipes, installed without cutting the line or stopping the process.

Clamp-on Ultrasonic 4–20 mA Pulse Modbus RTU
AM-ULM Ultrasonic Level Meter

AM-ULM

AM-ULM Ultrasonic Level Meter

Non-contact ultrasonic level meter for open tanks, sumps and channels, with a small blind zone and a Modbus output.

Ultrasonic 4–20 mA Pulse Modbus RTU
AM-ULM-B Small Blind Area Ultrasonic Level Meter

AM-ULM-B

AM-ULM-B Small Blind Area Ultrasonic Level Meter

Short-span ultrasonic level meter for shallow wells and tanks: 0–3 m, blind zone under 0.1 m, ±0.15 % and 1 mm resolution, 4–20 mA or Modbus.

Ultrasonic 4–20 mA RS485 Modbus RTU
AM-ULM-D Ultrasonic Level Differential Meter

AM-ULM-D

AM-ULM-D Ultrasonic Level Differential Meter

Two-probe ultrasonic differential level meter: 0–25 m difference range, ±0.5 %, two relays, 90–240 V AC or 12–24 V DC, 4–20 mA and Modbus.

Ultrasonic 4–20 mA RS485 Modbus RTU
AM-ULM-EX Explosion-proof Ultrasonic Level Meter

AM-ULM-EX

AM-ULM-EX Explosion-proof Ultrasonic Level Meter

Explosion-proof ultrasonic level meter for hazardous areas: Ex db ia IIC T6 Gb, 0–30 m, ±0.5 %, 1 mm resolution, 4–20 mA and RS485.

Ultrasonic 4–20 mA RS485 Modbus RTU
AM-ULM-S Split Type Ultrasonic Level Meter

AM-ULM-S

AM-ULM-S Split Type Ultrasonic Level Meter

Split ultrasonic level meter for deep wells, silos and tanks: 0–30 m, blind zone 0.25–0.8 m, ±0.5 %, 10 m cable extendable to 70 m.

Ultrasonic 4–20 mA HART RS485
AM-USM Ultrasonic Sludge Level Meter

AM-USM

AM-USM Ultrasonic Sludge Level Meter

Ultrasonic sludge blanket and interface meter for settling tanks, measuring the sludge line and the clear-water interface from a fixed top mount.

Sludge / Interface 4–20 mA Modbus RTU
AM-VFM Vortex Flow Meter

AM-VFM

AM-VFM Vortex Flow Meter

Vortex flow meter for liquid, gas and steam — DN15–DN300 full bore, ±1 % of reading, pulse or 4–20 mA, IP65.

Vortex Pulse 4–20 mA