AM-USM Ultrasonic Sludge Level Meter

Sludge / Interface

AM-USM Ultrasonic Sludge Level Meter

Ultrasonic sludge blanket and interface meter for settling tanks, measuring the sludge line and the clear-water interface from a fixed top mount.

Model
AM-USM
Category
Sludge / Interface
Outputs
4–20 mA, Modbus RTU
Lead time
7 working days; an on-site commissioning check adds 3 working days
MOQ
1 unit
OEM available
Yes

Technical specifications

AM-USM Ultrasonic Sludge Level Meter at a glance
Measurement Sludge blanket level and interface, 0.3–10 m
Principle Dual-frequency ultrasonic, fixed-top installation
Accuracy ±1% of range in stable sludge
Outputs Two 4-20 mA channels, RS485 Modbus, relay per threshold
Protection IP68 probe, IP65 controller
Installation Fixed mount on the tank bridge or a handrail bracket

What it is not the answer for

Read this before asking for a price: one of these conditions is what turns a good meter into a bad installation.

  • Thin, well-mixed sludge where no clear interface exists to measure
  • Tanks with mechanical scrapers passing within the probe's measurement path
  • Very deep tanks beyond the stated range

Maintenance and service life

Clean the probe monthly in heavy sludge service. Re-run the blanket calibration after any change to the sludge draw-off schedule, because the profile, not the instrument, has usually changed. The probe has no moving parts.

Content plan — certificates and case references

  • The declarations that apply to this model: CE, RoHS and any hazardous-area approval, each with its certificate number and the body that issued it.
  • One or two installations: plant type, medium, model supplied and what the reading is used for. Customer name only where written permission exists.

Measuring point does not match the table above?

Send the medium, the pipe size and the output your control system expects. We answer with the principle that fits, or with the reason none of ours does.